Detector Technology
DeTech Home Page DeTech's History DeTech's product offering DeTech's technical notes Global distributors of DeTech products Contact DeTech
 

 

DeTech 2300 replacement for Agilent 5973

Detech 2300
Replacement Horn for Agilent 5973

DeTech 2300 measurements
DeTech 2300 installation
Plug in Multiplier Compatible with HP 5970, 5971, 5971A, 5972, 5973 and 5989

DeTech Multipliers for Agilent

Detector Technology, Inc. was the first company to work with end users to develop a replacement detector for the standard Agilent Plug-In element. DeTech Model 2300 was designed to give the end user several performance benefits over the standard element, as well as a cost benefit.

DeTech Model 2300 Performance Benefits

Vented Anode – Detector Technology, Inc. has added vent holes to the anode of the detector. These vent holes allow for residual gases in the detector channel and anode to be removed during pumping. By removing these gases, the performance and life of the detector is improved.

Grid – When input ions enter the horn of a detector secondary electrons are created. These electrons should travel down the channel of the detector, but occasionally the secondary electrons travel out of the horn. Detector Technology, Inc. has placed a grid on the horn causing all secondary electrons to travel down the detector channel. This increases the signal to noise ratio and the overall performance of the detector.

Lower Operating Voltage – DeTech Model 2300 operates at a lower voltage than the standard Agilent element. The tuning voltage of Model 2300 is typically 1000V - 1200V. By starting detector operation at a lower voltage the overall lifetime is increased.

Increased Signal : Noise Ratio – When using Model 2300 in an Agilent instrument the signal to noise ratio of the instrument is increased approximately 25%. This is due to the mechanical design changes incorporated into the product, as well as the optimized channel length.

Robust Design – DeTech Model 2300 has a robust stainless steel frame to protect the glass detector from damage.

AutoTune plot graph for DeTech 2300
Application Specifications Model Number 2300
Maximum bake temperature 300°C
Maximum operating temperature 200°C
Mode of operation Analog/Pulse Counting
Typical gain at 2050 volts 1 X 10
Typical bias current >21 Micro Amps
Resistance 50-100 Meg Ohms
Maximum linear output current 10% of Bias Current
Dark Noise <.05 cps
Pulse Height Distribution >120%
Pulse Width >18-20 nSec
Rise Time >3-5 nSec
Instrument DeTech Model  
Agilent 5973
Plug-In Element for all Agilent 5973 Mass Spectrometers 2300  
Agilent 5971, 5971A, 5972 MSD
Full assembly and frame for Agilent 5971, 5971A and 5972 MSD 2373  
Replacement Horn Only for Agilent 5971/71A/72 MSD 2300
Replacement for K&M frame Large Horn 2300KM  
DeTech Multiplier 2300DeTech Multiplier 2300KMDeTech Multiplier 2373  
Agilent 5970 & 5993B MSD DeTech 306

EM for Agilent 5970 MSD306

 

306
Agilent 5989 MS Engine DeTech Multiplier 359

EM for Agilent 5989 MS Engine (conversion dynode included)

 

359
Agilent 5985/85B/87/88/88A DeTech Multiplier 305

EM for Agilent 5985/85B/87/88/88A
Positive Ion only

 

305
Agilent 5930/80/80A/81/82/83/84/85/85B/87 DeTech Multiplier 303
EM for Agilent 5930/80/80A/81/82/83/84/85/85B/87
Positive Ion only
303